Job Information
Siemens Testing Engineer in Thane, India
Job Family: Customer Services
Req ID: 426474
• Relay Testing Knowledge on software like MICOM S1 Studio, DIGSI and PCM for extracting and analysing of Disturbance Records and Events Log of AREVA, SIEMENS and ABB make relays.
• Knowledge of Transformer Testing (Tan-Delta Testing, Winding Resistance Test, Vector Group Test, Oil Test, Ratio Test and Partial Discharge Test).
• Knowledge of in Reactor Testing (Tan Delta Testing, Winding Resistance Test, Insulation Resistance Test, Oil Test, Partial Discharge test and Reactance Measurement Test).
• Knowledge of CT & PT Testing (Winding Resistance Test, Insulation Resistance test, Ratio Test, Polarity Test and Primary Injection Test).
• Sub-stations 220KV/33KV/6.6KV/415V, electrical distribution system, Audit, Legal, Safety, Meetings with Siemens Back office, Kaizen & improvement, Client Handling, Site team Handling
Experience Requirements:
• Knowledge in software’s like Wavewin32, Micom S1 Agile, PCM 600, Archive Crawler, Archive Reporter, System Configuration Editor (SCE), System Maintenance Tool (SMT), Computer Maintenance Tool (CMT) and Omicron Test Universe.
• Knowledge on Line Protection (Distance Relay), Reactor Protection (Differential, Backup Impedance & REF), Transformer Protection (Differential, REF, Bucholtz, Oil Surge Relay, Pressure Relief Valve, On Load tap Changer, Off Load Tap Changer, Overcurrent and Earth Fault includes HV, IV & LV) and Bus Bar Protection (Differential).
• Worked on Omicron CPC 100, CPC 356 and CP TD 12/15.
• Relay operation and trouble Shooting of Siemens (7SJ62, 7SJ64), Micom (P132, P141), GE and ABB Numerical relays
• Relay testing by using Omicron CMC 356 and Megger MPRT 8430
• Knowledge on software like MICOM S1 Studio, DIGSI and PCM for extracting and analysing of Disturbance Records and Events Log of AREVA, SIEMENS and ABB make relays.
• Knowledge on testing of Voltage chords and power chords of protection relays include Siprotec 7sj6221/7sj6222, Areva P132/ P141 and ABB Ref 615 and analysing the fault and reporting it to client.
• Experience in HT Breaker Operation, Maintenance, Servicing, Troubleshooting & Testing in 6.6KV SF6 & 6.6 KV VCB Breaker Make Siemens, ABB & Areva
• Operation and maintaining of Transformers 2 MVA, 2.5 MVA, 20 MVA & 27 MVA make Voltamp
• Planning & Performance of daily / monthly / annual maintenance of breakers, 6.6 KV VCB (Siemens), ACB (Siemens), Capacitor Banks, Battery chargers and battery banks and VFD panels
• Should have an ability to identify and troubleshoot the malfunctions, replacing parts and components.
• Should be familiar with safety procedures while carrying out electrical work
• Keep good Coordination and Communication, good relationship with Team members and Client
• Should be familiar with Report preparation MIS, Root Cause Analysis, PPT & Excel.
• Supported operation team on all erection, commissioning, testing & maintenance related issues.
• Knowledge of Current Control Unit (CCU) used for WTI, OTI, OLTC Tap Position reporting to SCADA.
• Knowledge on 220kV Switchyard, 33kV ABB GIS and 33 kV/ 6.6 kV/ 415 V AIS Substations
• Knowledge on Ethernet Switch (EFS), Ethernet Cable (RJ45), Fibre Optic Patch cable (Armored & Un Armored), Coaxial Cable (GPS) and Fibre Optic TCP/IP Ring.
• Knowledge on Synchronism check parameters.
• Knowledge on Tie Protection i.e. Local Breaker Backup (LBB).
• Knowledge on Auto-Recloser, SF6 gas Lockout, Phase Discrepancy, SF6 gas Alarm, CB closing Interlocks, Control Switching Device Interlocks (RPH3) and emergency CB tripping conditions.
• Analyzing the cause and effect of faults through Disturbance Records & Events Log extracted from the Relay and preparing Root Cause Analysis and submitting to client.
• Knowledge of Transformer Testing (Tan-Delta Testing, Winding Resistance Test, Vector Group Test, Oil Test, Ratio Test and Partial Discharge Test).
• Knowledge of in Reactor Testing (Tan Delta Testing, Winding Resistance Test, Insulation Resistance Test, Oil Test, Partial Discharge test and Reactance Measurement Test).
• Knowledge of CT & PT Testing (Winding Resistance Test, Insulation Resistance test, Ratio Test, Polarity Test and Primary Injection Test).